GSM/SMS/GPRS/FTP Remote
Control Module BieneRemote128GM, BieneRemote1281GM, BieneRemote1282GM
(OEM) GSM Remote
Control and Monitoring, Temperature monitoring with Pt1000 (Pt100) temperature
sensor (-4Pt1000/4A), Temperature and Humidity monitoring with Sensirion SHT11
sensor (BR128GM-SHT), Internal control (all BR128x modules).BieneRemote128GM-4Pt1000
- module with built-in GSM modem and 4-input Pt1000 adapter (with Universal Transducer-Interface
UTI) designed to be used for remote control, monitoring and alarming via GSM (for
temperature monitoring, analog and digital signal monitoring). BieneRemote128GM-4A
- without 4-input Pt1000 adapter and without temperature control. New function
- internal control without SMS sending and 4 level for analog signal and for temperature.
Data Logger function - temperature, analog and digital data - file transfer to
FTP server via GPRS. Heater resistor auto control possibility (BR128xGM-4Pt1000)
 |
with build-in GSM modem Telit GM862 
|
BR128GM modules support internal control and
module module communication. Internal control
- Output control from input events. Module-Module communication via SMS- output
control from input events on remoted modules. Internal control examples.
- digital event inut 1 - output 1 ON - digital event inut 2 - output 1 OFF -
temperature < MIN - heater ON - temperature >MAX - heater OFF - analog
level < MIN - output 3 ON (for example - Pump ON) - analog level > MAX
- output 3 OFF (for example - Pump OFF)
BieneRemote128xGM


|
GSM modules for Pt1000 (Pt100) temperature sensors support.
GPRS/FTP Data Logger. BieneRemote1281GM-4Pt1000, BieneRemote1283GM-4Pt1000
- module with 4 Pt1000 temperature inputs (with Smartec Universal Transducer-Interface
UTI). For 4 Pt1000 (Pt100) temperature sensors connection. Also 4 analog inputs,
6 digital inputs and 5 outputs. Designed to be used for remote control, monitoring
and alarming via GSM (for temperature monitoring, analog and digital signal monitoring).
Data Logger function -analog and digital data - file transfer to FTP server via
GPRS. Board size: 165 x 145 mm. BieneRemote1281GM-4Pt1000
- with Power Supply on board BieneRemote1283GM-4Pt1000
- without Power Supply.
BieneRemote1281GM-4A, BieneRemote1283GM-4A
- with 4 analog inputs, 6 digital inputs and 5 outputs. New function - internal
control without SMS sending and 4 level for analog signal. Data Logger function
-analog and digital data - file transfer to FTP server via GPRS
Modules
support internal control and module module communication. Internal control
- Output control from input events. Module-Module communication via SMS- output
control from input events on remoted modules.
| Features:
- All GSM range compatible (GSM 850/900/1800/1900) - Data Logger function
via GPRS/FTP - Module to Module communication and management - Internal
management without SMS - Notification with SMS - Temperature monitoring
(for Pt1000 temperature sensor); with adapter #Pt1000 - Digital signal monitoring
- Analog signal monitoring (if use adapter #4A, can set 0-5V or 0-10V or 4-20mA
inputs) - Configuration with PC or SMS - FTP-CSV-monitoring software for
BR128GM, BR1281GM, BR1283GM (optional) - Heater resistor auto control possibility
(BR128xGM-4Pt1000) BieneRemote128GM
data
sheet
new version data sheet 
BieneRemote1281GM-4Pt1000 - with Power Supply on
board
data
sheet BieneRemote1283GM-4Pt1000
- without Power Supply.
data sheet
FTP-CSV monitoring software for BR128GM, BR1281GM,
BR1283GM 
BieneRemote128GM-SHT -
for temperature and humidity monitoring  (for Sensirion humidity/temperature
sensor SHT1x, SHT7x).
m2m
(machine-to-machine) technology: Applications from telematics to personal
security; m2m enables automated communication between a remote equipment
and central management application, or between remote equipment and other remote
equipments; for example, automatically notify service centers and service
personal of maintenance issues. connecting external equipment to other external
equipment; connecting external equipment to service personal; connecting
external equipment to service centers;
 for external equipment
to other external equipment communication and management Module - Module
communication Module - service personal communication Internal control
without SMS External control with SMS Notification with SMS and GPRS/FTP
Data Logger to FTP
BieneRemote128GM Hardware Specification
| | BR128GM-Pt1000 |
BR128GM-4A |
BR128GM-SHT | | Communication |
via GSM GSM 850/900/1800/1900 | | Command
and data transmission | SMS/GPRS/FTP |
| Internal GSM modem |
Telit GM862-QUAD | | SIM
card reader | Yes |
| SIM card type | phase
2 GSM11.14 - SIM 3V | | Firmware |
Yes | | Digital
inputs | |
| Number of digital inputs | 6
(+1 optional) | | - Transistor digital input
| 6 (+1 optional) ("0": 0...+1V; "1":
+1.5…+12V without external limited resistor) | |
- Events digital inputs | 6
(+1 optional) | | - Digital signal filter |
25ms - 9 sec |
| Temperature sensor inputs | |
| Number of temperature inputs |
4 | - |
1 | | Temperature events
inputs | 4 |
- | 1 |
| Temperature sensor type |
Temperature sensor Pt1000 |
- | Temperature/Humidity
sensor SHT1x, SHT7x  |
| Temperature range |
-99 to +149 °C or -146 to 300°F |
- |
-40 to +120 °C | | Events
Temperature range | -99
to +149 °C or -146 to +300 °F |
- | -40
to +120 °C | | Accuracy |
0.2°C or 0.4°F |
- | - |
| Analog inputs | |
| Number of analog inputs | 4 |
4 | 3 |
| 0...+5V / 0...+10V,
0-20mA/4-20mA 100kom typ (with adapter #Pt1000) |
0...+5V / 0...+10V, 0-20mA/4-20mA 100kom typ
(with adapter #4A) | 0...+5V
100kom typ | | - Analog event inputs |
4 | 4 |
3 | | ADC resolution |
10 bit | | Outputs |
| | Number of outputs |
5 | | - MOSFET transistor
outputs | 4 (MOSFET SST5NF20V, 20V
max) | | - Relay outputs |
1 (NO, NC, COM; 24VDC/1A max
120VAC/0.5A max) | | - impuls output |
1 (output 4) | | Data
Logger (optional) | | | - Time
interval | 30 sec ... 300 sec |
| - Logged parameter | temperature,
analog data, digital input and output, status | | -
Output source | RS232 and FTP |
| Power Supply | |
| Required Power supply | External
+12 VDC stabilized | | Power requirement |
800mA(rms) max, 2A peak during transmission |
| Voltage regulator |
Internal voltage regulator | | Power
protection | Reverse-polarity protection |
| Environmental Conditions | |
| Normal operational temperature range |
-10…+55°C | | Extreme operational
temperature range (these temperature can affect the sensitivity and performance
of the module) | -20…+70°C |
| Phisical parameter | |
| Board dimension | 100x62mm |
| | |
BieneRemote128GM Firmware Specification
| | BR128GM-Pt1000 |
BR128GM-4A |
BR128GM-4A | | Number
of controlled outputs | 5 |
| Number of digital event inputs | |
| Number of readable digital inputs | |
| Number of temperature event inputs | 4 |
- | 1 |
| Number of analog event inputs | 4 |
| Number of readable analog data | 4 |
| Authorization cell phone numbers | 7 |
| Events cell phone numbers | 4
(external cell phone) +3 (external BieneRemote module) | | SMS
events format | Text
message | | SMS digital data format |
Binary | | SMS
message format for analog data | In
% from Reference level 00 - 99 | | Metric system
temperature | °C
or °F | - |
°C | | SMS message format
for temperature data |
min level 2, min level 1, max level 1, max level 2 measurement -99°C
- +149°C -146 to 300°F events level -99°C - +149°C
-146°F - +300°F | - |
min level 2, min level 1, max level 1, max level 2 measurement
-40°C - +120°C |
| | BieneRemote128GM |
| Version |
without adapter |
-4A with adapter #4A |
-Pt1000 with adapter #PT1000 |
-SHT without adapter |
| Data Sheet | | | Module |
|
|
|
|
| Adapter |
- |
|
|
| | Prospectus |
|
| Temperature Sensor |
- |
- |
|
SHT1x,SHT7x  |
Humidity Sensor SHT1x, SHT7x |
- |
- |
- |
|
Pressure Sensor SDP1000,SDP2000 |
|
|
|
|
|
SMS
in EEPROM | Temperature
Events | | 1 | T1
< min level 2 | | 2 | T1
< min level 1 | | 3 | T1
normal | | 4 | T1
> max level 1 | | 5 | T1
> max level 2 | | 6 | T2
< min level 2 | | 7 | T2
< min level 1 | | 8 | T2
normal | | 9 | T2
> max level 1 | | 10 | T2
> max level 2 | | 11 | T3
< min level 2 | | 12 | T3
< min level 1 | | 13 | T3
normal | | 14 | T3
> max level 1 | | 15 | T3
> max level 2 | | 16 | T4
< min level 2 | | 17 | T4
< min level 1 | | 18 | T4
normal | | 19 | T4
> max level 1 | | 20 | T4
> max level 2 | | |
SMS
in EEPROM | Analog
Events | | 21 | A1
< min level 2 | | 22 | A1
< min level 1 | | 23 | A1
normal | | 24 | A1
> max level 1 | | 25 | A1
> max level 2 | | 26 | A2
< min level 2 | | 27 | A2
< min level 1 | | 28 | A2
normal | | 29 | A2
> max level 1 | | 30 | A2
> max level 2 | | 31 | A3
< min level 2 | | 32 | A3
< min level 1 | | 33 | A3
normal | | 34 | A3
> max level 1 | | 35 | A3
> max level 2 | | 36 | A4
< min level 2 | | 37 | A4
< min level 1 | | 38 | A4
normal | | 39 | A4
> max level 1 | | 40 | A4
> max level 2 | | |
SMS
in EEPROM | Digital
Events | |
41 | Input 1 0-1 |
| 42 | Input 2 0-1 |
| 43 | Input
3 0-1 | | 44 | Input
4 0-1 | | 45 | Input
5 0-1 | | 46 | Input
6 0-1 | | 47 | Input
7 0-1 | | 48 | Input
1 1-0 | | 49 | Input
2 1-0 | | 50 | Input
3 1-0 | | 51 | Input
4 1-0 | | 52 | Input
5 1-0 | | 53 | Input
6 1-0 | | 54 | Input
7 1-0 | | Nr
| admin
cell phone number in SIM Phone Book |
| 1 | Number 1 |
| 2 | Number
2 | | 3 | Number
3 | | 4 | Number
4 | | 5 | Number
5 (external BR) | | 6 | Number
6 (external BR) | | 7 | Number
7 (external BR) | 
| |